BSS Audio TCS 80X Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria do paneli płaskich BSS Audio TCS 80X. BSS Audio TCS 80X User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User Manual

1FPC900rUser Manual

Strona 2

VARICURVE10TMS Y S T E MThe mains voltage selector switch provides a simple external adjust-ment to allow operation on all international AC

Strona 3 - Quick Start - Quick Reference

11Quick ReferenceConnect MIDI Outs to MIDI Ins in a daisy chain backto the Interface. Set FCS-926s and FCS-920s todifferent MIDI channels, and set FCS

Strona 4

VARICURVE12TMS Y S T E MData ConnectionsMidiSince the remote stores within it all data concerned with eachVaricurve unit, it is first essent

Strona 5 - Contents

13FSK2.8 FSKAn FSK (Frequency Shift Keying) communications channel is includedfor operation over long microphone cables, or over a standardmusicians

Strona 6

VARICURVE14TMS Y S T E MQuick ReferenceConnect the umbilical between the remote andinterface so that the charger can keep the batterycharged

Strona 7 - 1.0 Introduction

15ily. The unit will remain energised for approximately 30 seconds afterwhich it will switch off automatically, unless a control is moved, whichstarts

Strona 8 - 2.0 Installation

VARICURVE16TMS Y S T E MBasic ControlsA NUMERIC KEYSThe NUMERIC KEYS have two independent modes, switching automatically as required by thec

Strona 9 - 2.3 Mains Power

17from the Speed Strip or the Event key in theEvent Select menu.Refer to Section 14.0 ‘Events’.F INDEXThe INDEX key will list index informationrelated

Strona 10 - VARICURVE

VARICURVE18TMS Y S T E MBasic ControlsG ON/CHECKWhen the Remote is connected to the Rack Interface (FPC-900i) through the umbilical cable it

Strona 11 - Data Connections

19O WIDTHThe WIDTH control will adjust the band-width of the currently selected filter.P FREQUENCYThe FREQUENCY control will adjust thefrequency of th

Strona 12

VARICURVE2TMS Y S T E MThis equipment has been tested and found to comply with the following European Standardsfor Electromagnetic Compatibi

Strona 13 - 2.8 FSK

VARICURVE20TMS Y S T E MUser-defined name for each of the 16 available devices. Refer toSection 4.2 'Selecting a device' - INDEX.

Strona 14

21This box gives a graphical representation of the battery chargeavailable if the remote is being operated using its internal battery. SeeSection 2.9

Strona 15 - Internal Battery

VARICURVE22TMS Y S T E MUser-defined name for each of the 16 available devices. Refer toSection 4.2 'Selecting a device' - INDEX.

Strona 16

23This box displays the band delay value, or values, for the currentlyselected device. Refer to Section 17.0 'Controlling OmnidriveDevices'.

Strona 17

VARICURVE24TMS Y S T E M3.3 RemoteConnectionsRemote ConnectionsThe front panel PCMCIA2 card slot allows the storage of data from theremote o

Strona 18

253.4 InterfaceControls andConnectionsInterface Controls and ConnectionsThe FPC-900i pink noise output can be turned on and off from theremote. Press

Strona 19 - Q BOOST/PARAMETER

VARICURVE26TMS Y S T E MThese leds indicate the percentage charge in the Remote battery whenthe remote is connected using the multicore umbi

Strona 20

274.0 Selecting a DeviceSelecting a DeviceNumeric KeysPress a Device key to select an individual device or channel.Press both Device keys on the selec

Strona 21

VARICURVE28TMS Y S T E MPressing the INDEX key displays a directory of all the device numbers.Each entry corresponds to a Midi channel. The

Strona 22

29Quick Reference1 Select a filter to adjust by pressing the Speed Strip.2 Adjust the filter using the Frequency, Width andBoost/Cut knobs.3 Press and

Strona 23 - MAIN DELAY I

3Quick Start - Quick Reference1 Check the Mains Voltage setting on the rear of the 900i Interface Unit andinstall into a rack. Connect the mains to th

Strona 24

VARICURVE30TMS Y S T E MThe current equalisation curve shown on the display should bethought of as being in a scratchpad or working area. A

Strona 25

31Note that the Gain of the current device is not adjusted automaticallyand so may need to be altered by the user if large amounts of cut orboost are

Strona 26

VARICURVE32TMS Y S T E MThe display can be scrolled up or down to see the peaks or troughs ofany heavily boosted curves. The View cursor can

Strona 27 - 4.0 Selecting a Device

33Quick Reference1 Press STORE.2 Turn the Parameter control to select a programnumber.3 Enter a name, if required, using the numeric keys.4 Press STOR

Strona 28

VARICURVE34TMS Y S T E MTurn the Parameter control to choose a program number to Store to.Programs 1 to 50 are device programs. Programs R1

Strona 29

357.0 RECALLRECALLQuick Reference1 Press RECALL.2 Turn the Parameter control to select a programnumber.3 Press RECALL a second time to load the EQ int

Strona 30

VARICURVE36TMS Y S T E M8.0 COMPAREQuick Reference1 Press COMPARE.2 Turn the Parameter control to listen to each of theavailable programs.3

Strona 31

37A full list of the programs already Stored in the device is available bypressing INDEX after the first press of COMPARE. Adjusting the sourceprogram

Strona 32

VARICURVE38TMS Y S T E MQuick Reference1 Press UTILS2 Select a menu item by pressing the speed stripdirectly below the required item.3 Turn

Strona 33 - 6.0 STORE

39PINK Turns the interface pink noise output on and off.LOKOUT Locks out various controls on the Remote to prevent tampering.MORE Returns to the main

Strona 34

VARICURVE4TMS Y S T E MUsing This ManualPlease Read This! - Using This ManualThis manual has been written to make the understanding andopera

Strona 35 - 7.0 RECALL

VARICURVE40TMS Y S T E M(Channel) [EQ IN, EQ OUT]Bypass switches the Varicurve device in and out of circuit.With EQ IN the device is in circ

Strona 36 - 8.0 COMPARE

41Utilities Sub-menu(Remote)Selecting XFER will access the Menu containing options linked withtransfering program data through the Midi port or over t

Strona 37 - WARNING!

VARICURVE42TMS Y S T E MQuick ReferencePress ALL or GROUP.Use the Device Keys to enter channels into, or removechannels from the Group.Adjus

Strona 38 - 9.0 Utilities Menu

43screen. See fig 10.1. The Group curve is always displayed as flat onentry, representing a starting point for all the members of the group. Anadjustm

Strona 39 - Utilities

VARICURVE44TMS Y S T E MALL is a special case of Grouping. Pressing the ALL key will open agroup containing all the available Varicurve chan

Strona 40

4511.0 RTA (Real Time Analyser)The FPC-900r has access to both its own internal Real Time Analyser,working on the remote RTA microphone input, and als

Strona 41 - 9.3 MORE sub-menu

VARICURVE46TMS Y S T E MRTA MenuDISP (Display) [OFF, DEVRTA, INTRTA, INTSPL]This item selects the display mode for the RTA and SPL bargraph.

Strona 42 - 10.0 Grouping - GROUP and ALL

47(Local) [OFF, A-WT, C-WT]This sets the weighting for the SPL Bargraph display and is onlydisplayed when DISP is set to INTSPL.Refer to Appendix 18.4

Strona 43 - 10.2 Group UTILS

VARICURVE48TMS Y S T E M12.0 Room Curve and Add CurveRoom CurvesQuick ReferenceRoom Curve will convert an RTA display of bars andconvert it

Strona 44

49RTA pattern. If the curve is too complex for the available filters toapproximate, the shape is simplified by smoothing. If the currentdevice is in S

Strona 45 - 11.0 RTA (Real Time Analyser)

5ContentsContentsQuick Start - Quick Reference 3Please Read This! - Using This Manual 4Table of Contents 4Quick Reference 4Index 4"Refer to:&quo

Strona 46

VARICURVE50TMS Y S T E MQuick Reference1 Press RTA, select AUTOEQ.2 Select the current RTA or a mixture of the stored RTAsas the present res

Strona 47

51& Return to the RTA menu and adjust the RTGAIN item to show thefrequency response of the pink noise across the analyser bars.Avoid the clipping

Strona 48 - 12.0 Room Curve and Add Curve

VARICURVE52TMS Y S T E MThe Contour box allows the user to select a response curve thatdescribes the desired frequency response for the room

Strona 49 - 12.3 ADD Curve

53Quick ReferencePress EVENT to enter the Event menu.Trigger an event by pressing the Speed Strip under theappropriate event box.Step through consecut

Strona 50 - 13.0 AUTO EQ

VARICURVE54TMS Y S T E MThe screen lists each available device in a similar format to the deviceIndex screen. If a device is identified by t

Strona 51 - Sources

55[Select to begin copy]All the program changes linked to each device will be copied into thedestination Event along with the source program name.When

Strona 52

VARICURVE56TMS Y S T E MINDEX with Events[Select to enter]Select EDIT to enter the Event Edit screen.Selecting DONE will return to the main

Strona 53 - 14.0 EVENT

5715.0 Transfer (XFER)The Transfer menu is used to pass information to and from the remoteand the Varicurve devices on the system. It should be used i

Strona 54

VARICURVE58TMS Y S T E MXFER (Transfer)PROGs 1 to 50 can be transferred between REMOTE and DEVICE.A complete Varicurve DUMP can be transferr

Strona 55

59Smart CardCARD Menu16.0 Smart CardThe Smart Card socket on the front of the remote is designed to usePCMCIA2 memory cards of between 128kbyte and 2M

Strona 56

VARICURVE6TMS Y S T E M6.0 STORE 336.1 Naming Programs 346.2 INDEX in Store mode 347.0 RECALL 357.1 INDEX in Recall mode. 357.2 Recalling Be

Strona 57 - 15.0 Transfer (XFER)

VARICURVE60TMS Y S T E MEach file will be saved from the current data area of the appropriatetype. Saving a curve will save the current equa

Strona 58

61[Enter Filename]Select DELETE to choose a file to delete from an SRAM card. Now turnthe parameter control to select a file from the file list or typ

Strona 59 - 16.0 Smart Card

VARICURVE62TMS Y S T E M16.2 Card TypesThe Smart Card interface requires 68pin PCMCIA2 compatiblememory cards. Attribute memory is not requ

Strona 60

63Controlling Omnidrive DevicesQuick ReferenceSelect an Omnidrive device using the Device keys.Select the value to adjust using the Speed Strip.Adjust

Strona 61 - CARD Menu

VARICURVE64TMS Y S T E MControlling Omnidrive DevicesThe variable labelled UNITS is purely an FPC-900 display variable andhas no link to the

Strona 62

65Main delayvalue18.0 Controlling Delay DevicesConnect a TCS 803 or 804 device as a 'spur' from the MIDI THRUsocket of another device on the

Strona 63 - Controlling Omnidrive Devices

VARICURVE66TMS Y S T E MIt is important to realise therefore that any settings in the TCS80Xdevices will be lost when first controlled by an

Strona 64

67WarrantyThis unit is warranted by BSS Audio to the original end user purchaser againstdefects in workmanship and the materials used in its manufactu

Strona 65

VARICURVE68TMS Y S T E MThe primary of the mains input transformer on the 900i Interface isprotected from high voltage spike interference by

Strona 66

69FUNCTION TRANSMITTED RECOGNISED REMARKSBASIC CHANNEL Default 1-16 X MemorisedChanged 1-16 XMODE X XNOTE NUMBER X XVELOCITY X XAFTER TOUCH X XPITCH B

Strona 67 - 19.0 Warranty Information

7Introduction17.0 Controlling Omnidrive Devices 6318.0 Controlling Delay Devices 6519.0 Warranty Information 6720.0 Appendix 6820.1 Transient Suppress

Strona 68 - 20.0 Appendix

VARICURVE70TMS Y S T E MFrequency Weighting20.4 FrequencyWeightingCharacteristicsFrequencyResponse-80-70-60-50-40-30-20-10010101625406310016

Strona 69 - Midi Implementation

71IndexIndexAA-weighting 47ADD Curve 47, 48, 49ADD Curve - PROG No. 49ALL 16, 42ALLDEVS 58AUTOEQ 33, 45, 48, 50, 51, 52AUTOEQ - START 51BBALIST 51batt

Strona 70

VARICURVE72TMS Y S T E MIndexGROUP 16, 28, 42, 43GROUP ASSIGNMENT 44GROUP UTILS 42, 43GROUP UTILS - GAIN 43GROUP UTILS - MUTE 43grouping 42H

Strona 71

73IndexRTA RECALL 47RTA ROOMCV 48RTA SOURCE 46RTA SPL WT weighting 47RTA STORE 47RTGAIN 51SShift key 28, 34SIG LED 13Smart card 24, 59, 63, 65Smart ca

Strona 72

VARICURVE74TMS Y S T E MUser Notes

Strona 73

75User Notes

Strona 74

VARICURVE76TMS Y S T E MUser Notes

Strona 76

VARICURVE78TMS Y S T E MUser Notes

Strona 77

VARICURVE8TMS Y S T E M2.0 InstallationAs part of BSS Audio’s policy of quality control, this product iscarefully checked before packing to

Strona 78

9Before connecting the FPC-900i interface to an AC power source,check that the voltage selector switch on the side panel is correctly set.If a change

Komentarze do niniejszej Instrukcji

Brak uwag